2do Paso...
Configuring DataGate/400 for TCP/IP Access
1. To
access DataGate/400 via TCP/IP, you will need to configure the AS/400 with the
following commands:
ADDJOBQE
SBSD(QINTER)
JOBQ(DG8_40/DG8_SVC)
MAXACT(*NOMAX) SEQNBR(11)
· where
QINTER is the name of the subsystem where DataGate/400 service will run. QINTER is highly recommended, however, other
subsystems may be used. The subsystem
that is used for the job queries must be set up with a proper routing entry in order
for DataGate service to start. This
routing entry must run the program QCMD in Library QSYS and have the compare
value of ‘
QCMDB’ or ‘*ANY’. If the subsystem has one of these routing entries, it may be used
for DataGate.
· where
Sequence Number, if not 11, must be the first available number for the
Subsystem.
ADDJOBQE
SBSD(QINTER)
JOBQ(DG8_40/DATAGATE) MAXACT(*NOMAX) SEQNBR(12)
· where
QINTER is the name of the subsystem where DataGate/400 jobs will run. This must be the same subsystem name as in
the first ADDJOBQE command above.
· Where
the Sequence Number, if not 12, must be the next available number for the
Subsystem.
2. To
enable access to DataGate/400 via TCP/IP, the DataGate/400 service program must
be started. To start the service program,
enter the command:
DG8_40/STRDG8SVR
3. Similarly,
to block access to DataGate/400 via TCP/IP, enter the command:
DG8_40/ENDDG8SVR
4. You
must name the AS/400 Database in Acceler8DB Database Manager using Work with
Database Names

donde
'AS400 DB' es el nombre que usa en el programa de AVR, '192.168.100.100' es el
numero
ip interno a nuestro AS/400 y el puerto 5042 que configura datagate en el as/400
'wrksvctble'
bajo 'Acceler8db' parametro, 'johnny' es un usuario valido en el as/400.
Fin